โมดูลการทำงาน ABB 07AC91 ใหม่และเป็นต้นฉบับ
หมายเลขสินค้า:
07AC91การชำระเงิน:
T/Tท่าเรือขนส่ง:
Xiamen Chinaเวลานำ:
IN STOCKสั่งซื้อ(ขั้นต่ำ):
1our website : https://www.kerienplc.com/
Kerien Automation Co., Ltd. is located in the beautiful coastal city-Xiamen, Fujian, China. It is one of the beautiful coastal tourist cities in Southeast China.
Invensys Foxboro,Invensys Triconex,Rockwell Allen-Bradley Relianc,Schneider Modicon,ABB,Siemens,GE FANUC,Yaskawa,Bosch Rexroth,Westinghouse,Woodward,Ovatin...etc.
The grounding screw is insulated due to the rubber between the cabinet body and the base, and the shielding busbar is insulated from the base. The field control station shall be grounded according to the regulations. That is, they are respectively connected to the grounding busbar of the field control station. The power ground of I/O cabinet and UPS are connected to the same ground to ensure equipotential. 2. Each hardware equipment operator station, engineer station, network switch, server host, system display, etc. shall be grounded by shell or directly connected to the electrical grounding grid. 3. The 40 terminal of the analog module of the I/O module, namely the negative terminal of DC 24V, is connected to the logic grounding bus, the logic grounding bus is connected to the shielding ground, and then connected to the general grounding bus. 4. Shielding ground The protective ground of the field control station shall be connected from the grounding screw under the cabinet to the grounding branch line, and the shielding ground of the field control station shall be connected from the grounding bus bar to the public connection board. 5. Grounding resistance test The resistance of the grounding system shall be tested to ensure that the grounding can meet the requirements of the control system manufacturer. 1 The shell, instrument panel, cabinet, box, box, cable trough, protective tube, support, base and other normal and uncharged metal parts of the electrical instrument that may have dangerous voltage due to insulation damage shall be grounded for protection. For local instruments and switches with power supply voltage not higher than 36V, protective grounding is not required when there are no special requirements in the design documents.
ก่อนหน้า:
โมดูลโปรแกรม ABB 07AI91ถัดไป:
ABB 3BSE043660R1 CI867K01 โมดูลควบคุมถ้า คุณมีคำถามหรือข้อเสนอแนะโปรดฝากข้อความถึงเราเราจะตอบคุณทันทีที่เราสามารถ!
หมวดหมู่
สินค้าใหม่
AB 1768-PA3 แหล่งจ่ายไฟอินพุต PLC ควบคุมอุตสาหกรรม อ่านเพิ่มเติม
2094-BC07-M05-M 2094-BC07-M05-S อเมริกัน AB Kinetix6200 ไดร์เวอร์เซอร์โว 2094BC07M05S 2094BC07M05S อ่านเพิ่มเติม
MFC075BOM2 MFC075B0T1 MFC075BOM16 Emerson บอร์ดอินเวอร์เตอร์ อ่านเพิ่มเติม
SPMA1422 Unidrive SPM Series โมดูลอินเวอร์เตอร์ไดรฟ์ อ่านเพิ่มเติม
EMERSON แปลงความถี่ EV1000-4T0037G พารามิเตอร์ทางเทคนิค อ่านเพิ่มเติม
© ลิขสิทธิ์: 2024 Kerien Automation Co., Ltd. สงวนลิขสิทธิ์.
รองรับเครือข่าย IPv6